Purpose
- Verification of LQT sensors (level, concentration, temperature). These sensors are used for AdBlue parameter measurement

Project Scope
- SENT (Single Edge Nibble Transmission) protocol decoding
- High accuracy positioning (± 0.01 mm) during level value testing and high resolution temperature measurement
- Communication with a variety of devices (NI cDAQ, Rohde&Schwarz power supply, Pico temperature data logger, Votsch heat chamber, Mitsubishi PLC connected with SMC servo, …)
- Creation of reports from all tests and storing results in customer central database

Solution Approach
- Application created in LabVIEW
- Focus on user friendly GUI for monitoring, configuration, manual control and automatic tests

Systems & Tools
- NI LabVIEW NI cDAQ
- Mitsubishi GX Works 2
- MR Configurator 2